Your water bill keeps climbing, but you’re not using any more water than before. Your water heater gave out years ahead of schedule. A supply line burst under a bathroom sink and you came home to a mess.

Three different problems. One hidden cause — and most Mesquite homeowners have never heard of it.

Your Water Pressure Is Probably Too High

A lot of Mesquite neighborhoods are served by elevated water towers. That gravity-fed system is great for fire protection, but it can push residential water pressure to 100 PSI or more.

Plumbing code caps safe residential pressure at 80 PSI. At 100 PSI, every fixture, valve, and appliance in your house is under constant stress it wasn’t designed for.

What High Pressure Destroys

Your water bill. High pressure forces more water through every faucet, showerhead, and toilet than they’re rated for. You’re paying for water you didn’t need to use.

Your water heater. The tank, the relief valve, and every connection take a beating. We’ve seen heaters fail years early in high-pressure homes — a replacement that didn’t have to happen.

Your supply lines. The flexible lines under your sinks and behind your toilets are the weakest link. At 100 PSI, a burst line isn’t a question of if — it’s when. And “when” usually means water damage on top of the plumbing bill.

Everything else. Faucets that won’t stop dripping. Toilets that run on their own. Dishwasher and washing machine valves failing early. Even voided manufacturer warranties — most appliance warranties require pressure under 80 PSI.

The Fix: A Pressure Reducing Valve (Plus an Expansion Tank)

A pressure reducing valve (PRV) installs on your main water line and holds your home’s pressure at a safe, steady 60–70 PSI — no matter what the tower is pushing.

One important detail: once a PRV goes in, your plumbing becomes a “closed” system, which means you also need a thermal expansion tank on the water heater. That’s code, and it’s included in our installation.

How Our PRV Installation Works

  1. We test your current pressure at an outdoor hose bib — you’ll see the reading yourself.
  2. We install the PRV on your main line and set it to 60–70 PSI.
  3. We install (or verify) the thermal expansion tank on your water heater.
  4. We re-test to confirm steady, safe pressure throughout the house.

Most installations are completed in a few hours, and the job protects everything downstream: the heater, the fixtures, the supply lines, and your water bill.

How to Know If This Is Your House

You can’t feel 100 PSI at the faucet. It just feels like “good water pressure.” The damage happens silently, over years. A pressure gauge on a hose bib tells the whole story in two minutes — if you’re seeing the symptoms above, call (214) 534-1468 and we’ll test it and show you the reading, then give you straight options. No pressure tactics — just the numbers.

Service Area

Based in Mesquite, TX, serving Garland, Rowlett, Rockwall, Forney, Balch Springs, east Dallas, and surrounding DFW communities.

Call Fixxer Company Plumbing

High water bill, a water heater dying young, or a burst supply line in Mesquite or the DFW area? Call (214) 534-1468 or book online. We always answer the phone.

Fixxer Company Plumbing — Drain • Water • Gas — Mesquite, TX — Master Plumber M38904. Financing from $500 to $25,000 available through Wisetack.